DT-ACG200G Chilled Mirror Precision Dew Point Meter

DT-ACG200G.jpg

◇ Introduction ◇ Function◇ Parameter◇ Product order◇ Download◇ Related products

Introduction

The DT-ACG200G Chilled Mirror Precision Dew Point Meter adopts an open design, and the split sensor can be installed in the sampling gas path or placed in the environment to be detected. The principle is that the LED light source emits light onto the mirror surface, the light reflected by the mirror surface is measured by the photoelectric sensor, and the occurrence of dew can be detected by using the change in light intensity measured by the photoelectric sensor; the control circuit controls the mirror surface temperature at the critical point of the dew condensation temperature, and the platinum resistance thermometer in the mirror surface transmits the measured cooling surface temperature data to the panel for display. This equipment has high precision, wide range, good stability and no drift, and is widely used in temperature and humidity metering work in metering units and other fields.

Function

☆ Intuitive graphic-guided UI with rich display content.

☆ Open-design structure with split humidity cold-mirror sensor and temperature sensor.

☆ 32-bit high-speed microprocessor + 24-bit ultra-low-power ADC for high-precision signal acquisition.

☆ Digital fuzzy control technology, intelligent algorithm, and automatic dew point balancing for rapid measurement.

☆ Smart fault diagnosis and self-alert system.

☆ User-friendly PC software for parameter configuration.

☆ Anti-interference modular design with electrical isolation.

☆ Intelligent mirror self-check and cleaning system.

☆ User-customizable analog signal output.

☆ Multi-communication interfaces: RS-232, USB, standard MODBUS RTU protocol.

Technical Parameters

Dew Point Meters

Parameter

Specification

Dew Point

-30°C to +90°C; 5%RH to 99%RH (non-condensing)

Measurement Accuracy

±0.15°C

Resolution

0.01°C

Repeatability

±0.05°C

Minimum Dew Point Measured at 20°C

-30°C

Response Time

+1°C/second

Mirror Material

Beryllium Copper

Main Body Material

Aluminum Alloy

Cable Length

3m, 5m, 10m

Dimensions

φ46×156mm

Weight

0.25kg

Temperature Sensor (Integrated)

PT100, Accuracy: ±0.1°C;

     Temperature Range: -50°C to 180°C

Temperature Sensor (Remote)

4-wire PT100, Accuracy: ±0.1°C, Cable Length: 3m

Environmental Conditions

     Temperature: -20°C to +70°C;
     Sampling Gas Conditions:
     Operating Temperature: -40°C to 90°C
     Pressure: 0 to 20 bar (290psi);
     Operating Pressure: 0 to 100kpa
     Flow Rate: Atmospheric (ambient),
     Flowing Sample Gas (0.3to 1L/min)

DT-ACG200G Chilled Mirror Precision Dew Point Meter
  • Online message

  • Your name
    Your title must be filled
  • Cellphone number
    Mobile phone number is required
  • whatsapp/wechat
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what is the content you want to consult?
  • Verification code: Please fill in the calculation result.
This article is read 24 Times
Previous:DTSL DHT-Pro Temperature and Humidity Sensors Automatic Calibration Platform

Contact us

DEARTO QR codeHeadquarter Address Tai'an High-tech Development Zone,  Shandong Province 
Telephon :+86 0538-5089056  +86 13953856217 
Fax : +86 0538-5059718 
After sale:+86 0538-5050959
Website : www.tadt.com.cn 
E-mail   :  tadtzdh@dearto.cn

Copyright© Tai'an Detu Automation Instrument Co., Ltd.             Lu ICP 14024757-1           Business license inquiry