We are proud to announce a significant technological advancement in ultra-low temperature calibration technology.

Our newly developed -120°C Dry Block Calibrator now achieves a groundbreaking performance:
Model | DTG-ULT120G | DTG-ULT100G | DTG-ULT80G | DTG-ULT60G | DTG-U42G | DTG-U30G | |
Temp. range (°C) | -120 to 40 | -100 to 40 | -80 to 40 | -60 to 40 | -42 to 150 | -30 to 150 | |
Display resolution (°C) | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | |
Dimensions | 192*320*530 | 199*328*364 | 170*320*330 | ||||
Display Accuracy (℃) | ±0.2 at (full range) | ±0.2 | |||||
Radial uniformity (°C) | ±0.1 at (full range) | ±0.2 | |||||
Stability (°C) | ± 0.03 at (full range) | ± 0.15 | |||||
Standard Block Insertion Hole Diameter (mm) | Block Diameter:30 | Ø4.5/Ø6.5/Ø8/Ø10 | |||||
The insertion depth and outer diameter of the sensor to be calibrated shall be specified upon ordering. Custom specifications are available. | |||||||
This level of precision at such an extreme low temperature is a world-leading achievement for a dry block design – no liquid medium required, ensuring safety, ease of use, and zero contamination risk.
Key Advantages
- Completely dry operation – no fluids, no mess, no maintenance
- Compact and portable for both laboratory and on-site calibration
- Intelligent touchscreen interface with automatic stability judgment and real-time data display
- Supports multi-point correction and full traceability to national standards
Primary Application Scenarios
- Low-Temperature Sensor Calibration Ideal for calibrating Type T/E/N thermocouples, low-temperature PRTs (Pt100/PT1000), and NTC thermistors in extreme cold conditions.
- Cold Chain & Vaccine Storage Validation Ensures accuracy of temperature loggers and sensors used in ultra-low freezers (-80°C to -120°C) for vaccines, biologics, and pharmaceuticals.
- Aerospace & Defense Testing Simulates cryogenic environments for temperature sensors in aircraft, satellites, and missiles.
- Scientific Research & National Metrology Supports reference-grade calibration in national institutes and research labs requiring extreme low-temperature standards.
- Industrial Process Control Verifies sensors in LNG (liquefied natural gas) systems and deep-freeze industrial applications.
This breakthrough reinforces DEARTO's commitment to innovation in metrology and calibration. We invite laboratories, calibration centers, and industrial partners worldwide to experience the performance of our -120°C Dry Block Calibrator.
| Previous:9th National Academic Conference on Temperature Measurement and Control Technology: A Gathering of Wisdom for Industrial Upgrade |




Tel
Product
Contact